Actions
Support #3163
closed
JS
The modbus engine doesn't detect the modbus response data
Support #3163:
The modbus engine doesn't detect the modbus response data
Status:
Closed
Priority:
Normal
Assignee:
-
Affected Versions:
Label:
Description
The suricata version is 4.1.4.
And I still send the modbus request data and response data.
But only see the modbus-detect-engine detects the request data.
So I want to know the 4.1.4 doesn't detect the response data or I run in a wrong way?
Thank you!
JS Updated by John Smith about 7 years ago
oh,I know why?Because these is no register to the modbus response data in detect-modbus.c
VJ Updated by Victor Julien about 7 years ago
- Assignee deleted (
Victor Julien)
AH Updated by Andreas Herz almost 7 years ago
- Assignee set to OISF Dev
- Affected Versions 4.1.4 added
VJ Updated by Victor Julien almost 7 years ago
Can you provide a test case (pcap)?
AH Updated by Andreas Herz almost 7 years ago
- Target version set to Support
VJ Updated by Victor Julien over 6 years ago
- Status changed from New to Closed
- Assignee deleted (
OISF Dev)
Actions